Regenerative drive for elevator 50A,18.5KW, Chopper Voltage 620V
Description of Regenerative Unit:
This series adopts 32 bit high-performance industrial MPU with fast
respond, high-accuracy process control, making the inverter operating in
four-quadrant, continuously feedback,and regenerative braking frequency
below 40%. Electric regeneration efficiency up to 97%. Using SPWM
modulation to greatly reduce distinctive peaks of current and form
perfect sine wave current, input side current THD lower than 5%, power
factor up to 99%.It can prevent power grid flowing back, overheating,
overcurrent, out of phase, undervoltage,and short circuit.
Sikes
regenerative unit can replace the conventional braking unit &
resistors , which collect the power usually wasted into heat and convert
it back into power grid . The advantages are obvious :
1: Collect the extra power generated by VFD instead of wasting it as heat , so cool down the equipment and extend service life .
2: By reducing the temperature of the equipment , it also reduce the load of cooling equipment , another saving on power cost .
Here are some application cases of SIKES Regenerator for elevator:http://sikes-elec.com/News-Sikes/Applications/Regenerator-for-elevator.html
Characteristics of this series:
Power range:7.5KVA-55KVARated current: 25-150A
Working DC power voltage: DC 310/620V(±5V)
Output AC power voltage : three-phase AC 220/380V
Operating frequency: 46-60Hz
Accuracy index: setting error less than 0.5%
Overload capability:110% long-term,150% 1min,180% 2s.
Working conditions: containing built-in intelligent fan, high and low order harmonic filter, external short circuit protection.
Protection class: IP20
Protection function: OCP,OVP,UVP,overheating protection and polarity protection.
Anti-jamming capability: meet the requirement of GB/T 15153.1(IEC60870-2-1) 4 class high-frequency interference test:
-Common mode:2.5KV, 1MHz, 2S
-Differential mode:1.0KV, 1MHz, 2SGB/T
EMC: Accord with GB/T 17626.4( IEC61000-4-4)4 class EFT interference test;GB/T 17626.3( IEC61000-4-4)4 class radiation EMF test;GB/T 17626.2( IEC61000-4-4)4 class ESD test.
Environmental ambient temperature: -10℃~+60℃(non-frozen)
Cooling mode: forced-air cooling
Installation method: wall-mounted, floor type
Standard: ISO,FCC,CE
Application of Regenerative Unit:
Dedicated for elevatorRegenerative drive and Braking unit | |
Efficiency | >97% |
IP Class | IP00 |
Nominal Current Range (A) | 50 |
Operating Frequency | 46-60Hz |
Output Voltage(V) | 400 |
Power range (KW) | 18.5 |
Chopper Voltage (V) | 620 |
Certificates : http://sikes-elec.com/Certificates.html
This is a Demo Shop. You can place your order, but please contact us before you pay.